Hot Tub Error Codes - Electronic Spa Packs (Control Systems)

Hot Tub Error Codes - Spa Topside Error Messages

1)  Hot Tub Error Codes (Alphabetical)

2)  Flashing Light Error Codes for Spas

Hot Tub and Electrical Wiring Error Codes

1)  Hot Tub Error Codes (Alphabetical)

 * * * (3 flashing dots under temp display)

 Flow/Pressure switch either Open or Closed Circuit

 * * * (as above, & red LED lit up on board)

 High Limit Fault
 - - - , - - -  ‘Watchdog’ - 48C reached, electronic fault, shuts system down. Major fault
 - 01 Hi-Limit fault
 - 02 Temp sensor fault
 - 03 Flow/pressure switch open
 - 04 Flow/Pressure switch closed
 - 07 Hi-limit fault
 ---

 “Watchdog” (spa is deactivated), likely a bad temp or hi-limit sensor or water temp has reached 118ºF

 --- Unknown water temperature. (Displays when first powered up after refill)
 
01
 Stuck Button
 
02
 No Controller Data
 
03
 Temperature Sensor
 
04
 Water Sensor
 
05
 Spa Over Temperature
 
06
 Heater Thermal Cut Out
 
07
 Stuck Heater Relay
 
09
 Water Prime Failed
 
131
 Hi-limit
 
A1/A2-ER
 Aux. system error
 
AOH
 Temp in Equipment compartment to high
 BJ2P Hi-Limit - water temp too high
 
BJ2P
 
 Pump/Blower purge - normal condition
 
BL-ER 
 Blower failure
 
C4.4
 
 Hi- Limit
 
C
 Celsius
 
Cd, CLd
 Freeze Condition
 
CE 01
 Stuck Touchpad button
 
CE 02
 No controller Data Communication
 
CE 03
 Temperature sensor fault
 CE 04 Water Sensor/Pressure switch fault
 
CE 05
 Over Temperature Condition
 
CE 06
 High Limit manual reset Klixon tripped
 
CE 07
 Stuck Relay
 
CE 08
 Temp Sensor Fault -( Spaquip Digital 2000 MK1 sensor)
 CE 09 Water Prime Fault - Lack of water
 
CL
 Current Time of Day
 
COL
 Cool condition. Water temp 20ºF below set temp. Low speed pump & heater activate
 
Cold
 Temp in heater housing is below 40° F. Low speed /circ pump will run until the temp rises above 45° F.
 
Cool, COOL, COL
 Water is 11C below set point - not a fault
 
COOL
 Spa water is more than 20° F cooler than the temperature set point
 
CP-ER
 Circ pump failure
 
DR, dr, dy?
 Inadequate water detected in heater.
 
dr
 Inadequate flow in heater.
 
dry
 Inadequate flow in heater. (Displays on third occurrence of “dr” message)
 
E### 
 pH probe out of calibration
 
E0 
 Short circuit temperature sensor
 
E1
 Open circuit temperature sensor or open temp sensor
 E2 Short circuit/closed high limit sensor or shorted hi-limit sensor
 E3 Open circuit high limit sensor or open hi-limit sensor
 E4 Short circuit/closed pressure/flow switch or shorted flow switch
 E7 Improper electrical connection
 
ECdu
 Economy Mode Duration
 
Ecn 
 Spa operating in Economy Mode
 
Econ
 Economy Mode Turn On
 
EO 
 Shorted temp sensor
 
Er0, Er1
 Temperature sensor faulty
 
Er2, Er3
 Hi-Limit fault
 
Er4 
 Flow/Pressure switch short circuit
 
err 1 
 (H20) Prime Failed
 
err 3
 Stuck Button
 
err 4
 No Water Sensor
 
err 5
 Over temp
 
err 6 
 Thermal Cut Out Tripped
 
err 7
 Stuck Relay
 
err 8
 No Temp Data
 
Err 
 Software Program Fault
 
Error 3
 Stuck touchpad button
 
Error 4
 Water sensor fault
 
Error 5
 Over temperature
 
Error 6
 Klixon Tripped - over temp
 
Error 7 
 Stuck Relay
 
Error 8
 Temperature sensor fault
 
F2
 4 hours daily filtration
 
F4 
 8 hours daily filtration
 
F6 
 12 hours daily filtration
 
 Fahrenheit
 
FB-ER
 Fiber optic failure
 
FC 
 continuous filtration
 
FL1 
 Flow problem/pressure switch malfunction. Check for low water or clogged filter. Ensure pump is primed.
 
FL2 
 Pressure switch problem. Switch closed while pump is deactivated
 
FL 
 Flow/pressure switch stuck in closed position or pressure switch or flow switch failure
 
FLC, FL2
 Flow/pressure switch closed circuit - debris in switch, perforated diaphragm.
 
FLC 
 Pressure switch failure, switch closed
 
Fldu 
 Filter Cycle Duration
 
FLO*
 Flow Switch (heater is deactivated. Pump may also be deactivated)
 
FLO, Flo, FL1
 Pressure switch open - lack of pressure OR for Sundance/Spa Builders/Balboa, pressure switch closed
 
FLO2 
 Closed or shorted flow switch on system startup
 
FLO (flashing)
 Flow switch open circuit - Sundance/Spa Builders/ Balboa
 
FLO 
 Pressure switch or Flow Switch malfunction (heater and/or pump may be deactivated)
 
Flon
 Filter Cycle Turn On
 
FN-ER
 Fan failure
 
FP 
 Freeze protect mode - temp under acceptable condition
 
Fr 
 Freeze condition - temp below 40 degrees
 
FrE
 Fr, FP Freeze condition detected
 
FrE 
 Possible freeze condition
 
FrEE 
 Freeze Protection Alarm
 
H2O 
 Water Prime Fault - lack of water
 
HFL
 Substantial difference between temperature sensors detected. Could indicate a flow problem
 
HiLi, HLEr 
 Water temperature above acceptable range
 
HL, HFL, HH, OHH
 High limit sensor reading 45-48C, or above - check flow
 
HL
 Temp above 118 degrees. High limit switch tripped
 
HLoH
 Hi Limit Over Heat. Hi limit sensor is disconnected, shorted, or spa temp is above 112° F
 
Hold 
 Panel buttons pressed to many times/quickly
 
HOT 
 Circuit Board temperature has exceeded acceptable limit. System will restart when temp. drops
 I CE2 Freeze protection. No action is necessary
 
IC 
 Freeze Condition
 
ICE 
 Freeze condition. 55ºF detected. Low speed pump and heater will activate until spa reaches 65ºF
 
ILOC 
 Interlock failure - possible pump/ozone spike - possibly caused by faulty ozonators, pumps and equipment
 
L1 
 Panel Lock
 
L2 
 Panel Lock
 
LF
 Persistent low flow. (Displays on 5th occurrence of “HFL” message with 24 hours). Heater is shut down
 
LO 
 Freeze Condition
 
LOC 
 Control Panel functions Locked
 
Loc 
 Panel / Keypad Locked
 
LS=0, LS=S
 Multiple causes - open circuit sensor, faulty panel connection, improper voltage, etc
 
O3-Er
 Ozone error
 
OH 
 High temperature condition, has reached 110ºF. Spa may be partially deactivated or low speed pump (and air blower if equipped) may activate to lower temp
 
OHH 
 Overheat. One sensor has detected 118º. Spa has shut down
 
OHS
 Overheat. One sensor has detected 110º. Spa has shut down
 
OP 
 Open circuit sensor
 
P1, P2 or P3-ER
 Pump 1, 2 or 3 failure
 
pd 
 Power supply interrupted, unit running on battery backup
 
PLUG 
 Sundance/Spa Builders Service Technician’s Test Plug accidentally left connected to PCB
 
PnL 
 Communication error between the panel and circuit board
 
Pr 
 System Priming - When spa is first actuated, it will go into Priming Mode
 
Prh 
 Hi-limit sensor failure
 
Prr 
 Temperature Sensors Alarm
 
PS 
 Flow or pressure switch failure
 
PSoC 
 Pressure switch open with circulation pump
 
PSoH 
 Pressure switch open with high pump
 
PSoL 
 Pressure switch open with low pump
 
Rly 
 Stuck Relay on In.XE
 
RH-HR
 Heater Hardware error
 
RH-NC
 Comm error to Pack
 
RH-NF
 No flow in heater
 
RH-NH
 Heat attempted & failed
 
SA, SnA, SnH, Sb, Snb, Snt 
 Sensor Open Circuit or faulty
 
SC-ER 
 System learning failure
 
SE
 Spa operating in Standard-in-Economy Mode
 
SEoP
 Sensor open or disconnected. Heater disabled but spa operational
 
SESH
 Sensor short, nonfunctional. Heater disabled but spa operational
 
SH 
 Short circuit sensor
 
Sn1 
 Hi-limit sensor malfunction
 
Sn2 
 Nonfunctional temperature sensor. Heater deactivated
 
Sn3 
 Temp sensor malfunction
 
SN 
 Non functional high temperature sensor. Heater is deactivated
 
Sn
 Sensors out of balance
 
Sna 
 Sensor plugged into jack A is not working. Spa is shut down
 
Snb 
 Sensor plugged into jack B is not working. Spa is shut down
 
SnH 
 Hi Limit circuit open or faulty
 
SnS 
 Sensors out of balance. If display shows only this message (blinking) spa is shut down
 
SnT 
 Temp sensor circuit open or faulty
 
SP-BR
 breaker setting to low
 
SP-F1,F2 or F3
 Fuse 1, 2 or blown
 
SP-HR
 hardware error
 
SP-IN
 Input voltage low
 
SP-OH
 Water temp over 112F
 SP-OT Temp inside skirt high
 
SS=0;SS=S;LS=O;LS=S
 Multiple causes; open sensors, bad connection to panel, improper voltage, etc.
 Std  Spa operating in Standard Mode
 
th2/current
 On startup indicates temperature probe problem
 
th3/39
 On startup indicates water temperature less than 39° F
 
thl/39
 temp probe problem
 
ToE
 Time out error. Rare system error. Spa unusable.
 
Tu 
 Temperature Set Celsius or Fahrenheit

 

2)  Flashing Light Error Codes

 
1 flash - 3 second gap
 High Limit fault
 
2 flashes - 3 second gap
 Pressure/Flow switch short circuit
 
3 flashes - 3 second gap 
 Pressure/Flow switch open circuit
 
4 flashes - 3 second gap
 Open circuit Sensor(s)
 
Flash - 1 second on, 1 second off
 Same as OH
 
Flash - briefly OFF once per second 
 Same as Sn1 or Sn3
 
Flash - briefly ON once per second
 Same as FLC
 
Blinking Power Indicator Light - Hydromate 
 High Limit tripped or, sensor fault
 
1 flash per second - onga 4352
 
 
53, 95, etc
 
 Pressure switch open circuit - could also be motor, or motor thermal overload
 
3 flashes per second - onga 4352
 
 
53, 95, etc
 Electronic fault - sensor (most common cause) or PCB
 
Green flashes - Spaquip Pulsar/2095 series
 Water sensor fault - lack of water
 
Red/Green alternate flashes
 Temperature sensor fault, open circuit, or high limit tripped - push Reset Rod